NEW QUESTION # 48
Which two of the following best practices are used when creating a universal device poller (UDP)? (Choose two.)

  • A. Perform SNMPwalk to determine if OID exists.
  • B. Call SolarWinds support for object ID (OID) options.
  • C. Consult vendor documentation for OID.
  • D. Run WBemtest to test communication to OID.

Answer: A,C

Explanation:
The best practices for creating a Universal Device Poller (UDP) in SolarWinds are:
Consult vendor documentation for OID: Always check the device/vendor documentation for the correct OID to monitor the desired metric.
Perform SNMPwalk to determine if OID exists: Use SNMPwalk to verify the OID's existence and see if it is supported and returns the correct values from the device.
Calling SolarWinds support is not a standard step for obtaining OIDs, and WBemtest is a Windows tool for WMI, not SNMP/OID polling.
Exact Extract from Official Guide:
"Consult device vendor documentation for correct OIDs and perform SNMPwalk to ensure the OID exists and is supported by the device before creating a UDP."
- (Network Performance Monitor Administrator Guide, "Best Practices for Universal Device Pollers" section) References:
Network Performance Monitor Administrator Guide, Best Practices for Universal Device Pollers


NEW QUESTION # 49
Which three of the following technologies are supported to create device studio pollers? (Choose three.)

  • A. Node details
  • B. Multi-CPU / memory
  • C. Single CPU / memory
  • D. VLAN details

Answer: B,C,D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Device Studio in SolarWinds allows you to build custom pollers for several device-level metrics. According to the SolarWinds Administrator Guide:
Device Studio can be used to create pollers for multi-CPU/memory, single CPU/memory, and VLAN details.
These templates allow you to monitor resource usage and VLAN assignments.
"You can build templates for node details, but those are standard node properties, not supported by Device Studio pollers." References:
Device Studio-supported poller types - SolarWinds NPM Administrator Guide, Device Studio section


NEW QUESTION # 50
Which two of the following processing policies are processed independently and at the same time? (Choose two.)

  • A. global post
  • B. svslog
  • C. global pre
  • D. traps

Answer: B,D


NEW QUESTION # 51
How does data collection with a flow collector differ from data collection with a polling engine?

  • A. flow data is processed by flow collector or polling engine
  • B. flow data is collected by flow collector and processed by polling engine
  • C. flow collector is a type of polling engine for flow data
  • D. source devices must be configured to send their data to a flow collector

Answer: D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Flow collectors differ from polling engines because they passively receive and process flow records sent by network devices, while polling engines actively poll devices for data (like SNMP). Devices must be explicitly configured to export their NetFlow, sFlow, or J-Flow records to the IP address and port of the flow collector, rather than being queried by the SolarWinds server.
The documentation states:
"To monitor flow data, devices must be configured to send their flow records to the collector. Unlike traditional polling, the collector does not initiate contact; it listens for incoming flow exports from network devices." References:
Network Performance Monitor Administrator Guide, Section: "Flow Collector Operation" SolarWinds NTA Documentation


NEW QUESTION # 52
What is the minimum amount of RAM required for setting up log collection in hybrid cloud observability?

  • A. 32 GB
  • B. 16 GB
  • C. 4 GB
  • D. GB

Answer: B


NEW QUESTION # 53
Which two of the following locations can be checked for network hardware health functionality? (Choose two.)

  • A. list resources
  • B. manage sensors
  • C. node properties
  • D. device view

Answer: A,C


NEW QUESTION # 54
How are additional collection ports added?

  • A. separate listed ports with a comma in the NetFlow collector services widget
  • B. stop SolarWinds' NetFlow service and change the collection port in the NetFlow collector services widget
  • C. stop SolarWinds' NetFlow service and separate listed ports with a comma in the NetFlow collector services widget
  • D. replace existing port with new port in the NetFlow collector services widget

Answer: C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To add additional NetFlow collector ports, you must stop the NetFlow service and then specify multiple ports separated by commas in the NetFlow collector services widget.
From the documentation:
"To configure multiple collector ports, stop the NetFlow service, edit the collector ports in the widget by separating them with commas, and then restart the service." References:
NTA Administrator Guide: Configuring NetFlow Collector Ports


NEW QUESTION # 55
What is the unit of data used for alerting on flows?

  • A. mbps
  • B. bPs
  • C. ms
  • D. gps

Answer: A

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
The standard unit for flow-based alerts in SolarWinds (e.g., NetFlow Traffic Analyzer) is megabits per second (mbps). Alerts regarding traffic rates, bandwidth utilization, and similar flow metrics are configured and displayed in mbps for consistency with network monitoring best practices.
Reference:
"Traffic flow alert thresholds are set and displayed in megabits per second (mbps) within the SolarWinds web console and NTA."
- (Network Performance Monitor Administrator Guide, Alerting on Flow Traffic section)


NEW QUESTION # 56
In which two of the following cases does duplicate flow data occur? (Choose two.)

  • A. IP flow ingress on some interfaces and egress on others
  • B. both IP flow ingress and egress applied for all interfaces
  • C. IP flow ingress applied on all interfaces, no egress usage
  • D. both IP flow ingress and egress applied on one interface

Answer: B,D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Duplicate flow data typically results when both ingress and egress flow monitoring are applied simultaneously on interfaces. If both directions are enabled either globally (all interfaces) or locally (on a single interface), the same flow is counted twice-once entering and once leaving-resulting in duplicate statistics.
Reference:
"To avoid duplicate flow data, do not enable both ingress and egress NetFlow on the same interface or across all interfaces. Doing so will cause the same packets to be exported twice and counted as duplicates in reports and charts."
- (Network Performance Monitor Administrator Guide, NetFlow configuration best practices section)


NEW QUESTION # 57
The web console is showing the status of a network router as "down", however the node is up and running.
Which two of the following causes could be creating the issue? (Choose two.)

  • A. agent connection status with the polling engine is "down'
  • B. ICMP is blocked between the device and the polling engine
  • C. router is configured as a parent in a node dependency
  • D. SNMP is blocked between the device and the polling engine

Answer: B,D


NEW QUESTION # 58
Which switch model is supported in Network Insight?

  • A. Juniper EX
  • B. Brocade G620
  • C. Meraki MX
  • D. Cisco Nexus

Answer: D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Network Insight in SolarWinds supports in-depth monitoring for certain advanced switch platforms.
According to the latest SolarWinds Network Performance Monitor Administrator Guide:
"Network Insight for Cisco Nexus provides advanced visibility into the health, configuration, and performance of Nexus switches. This includes inventory, configuration changes, interface health, VDCs, and more." Other switch families such as Brocade, Juniper, and Meraki are not currently supported by Network Insight.
References:
Network Performance Monitor Administrator Guide, Section: "Network Insight for Cisco Nexus"


NEW QUESTION # 59
What is required to submit an MIB database update request to SolarWinds?

  • A. specific object ID (QID) for polling
  • B. polling interval to monitor the metric
  • C. type of widget to populate data
  • D. SNMP or MIB walk from the device

Answer: D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To request an update to the SolarWinds MIB database, you must provide a complete SNMP walk or MIB walk from the device in question. This allows SolarWinds to identify and incorporate new OIDs and their definitions into the database.
From the documentation:
"Submit a request with a full SNMP walk or MIB walk output from your device. This provides the necessary OID and device structure for the SolarWinds team to update the MIB database." References:
NPM Administrator Guide: Submitting MIB Update Requests


NEW QUESTION # 60
In device studio, the test node being built for a new custom poller is returning four usage values for the CPU (one for each CPU core). If the goal is to have one value for the entire CPU, how can that be accomplished?

  • A. create a new calculated value to average the four individual values
  • B. device studio would not be the correct tool to use in this situation
  • C. values can be combined after the poller is created in poller settings
  • D. there is not an object ID (OJD) for CPU usage, nothing can be done

Answer: A

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Device Studio allows you to define calculated values based on multiple polled results. To aggregate per-core CPU usage into a single metric, you can create a calculated value (such as the average) using the outputs from all cores.
From the documentation:
"Device Studio enables you to define calculated values (such as sum or average) when multiple SNMP values are returned, allowing you to represent a total or average CPU usage." References:
NPM Administrator Guide: Device Studio Calculated Values


NEW QUESTION # 61
In which scenario would the device studio poller tool be considered the best tool for building a required poller?

  • A. Building a poller for ARP tables to display in the web console.
  • B. Building a poller to add missing information to node details.
  • C. Building a poller to show CPU and memory status.
  • D. Building a poller to monitor VPN tunnel status.

Answer: B


NEW QUESTION # 62
A device studio poller is being built for a router statistic. It is determined that its object ID (OID) does not exist in SolarWinds' MIB database. What is the best workaround for this situation?

  • A. select manually define object identifier and specify SNMP
  • B. download database from customer portal
  • C. select SNMP and ICMP as the router's polling method
  • D. consult vendor and add OID to the database

Answer: A


NEW QUESTION # 63
If an SNMP community string is changed on a device, which two of the following steps are required to re- establish successful polling on the node? (Choose two.)

  • A. Restart the SNMP service on the source device.
  • B. Update the community string in node properties.
  • C. Edit the node properties and save the changes.
  • D. Delete and add the node back into the platform.

Answer: B,C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When the SNMP community string is changed on a device, SolarWinds recommends:
Edit the node properties and save the changes.
Update the community string in node properties to match the new value on the device.
"To restore polling, edit the node in SolarWinds, update the SNMP community string in the properties, and save the changes. This ensures that SolarWinds can authenticate and resume polling. Deleting and re-adding the node is not necessary, nor is restarting the SNMP service on the device in most cases." References:
Network Performance Monitor Administrator Guide, Section: "SNMP Node Management" SolarWinds Success Center: "Updating SNMP Credentials"


NEW QUESTION # 64
It is noted in flow source view that some devices are showing "never received" in the last received flow column. It is verified that the flows are not being blocked by a firewall. What is the likely cause?

  • A. interface is no longer monitored by the network monitoring features
  • B. a primary field of data is missing and being dropped
  • C. flows are IPv6 and not supported by the network monitoring features
  • D. node is no longer monitored by the monitoring features

Answer: B


NEW QUESTION # 65
After creating a new device studio poller that appears to be returning values on a test device, it is then applied to additional nodes. One of these new devices is not returning the statistics of the test node. Which two of the following reasons might be the cause of the issue? (Choose two.)

  • A. object IDs (QIDs) are not supported
  • B. new device needs to be rebooted
  • C. communication issue exists in new device
  • D. devices have different firmware versions

Answer: A,D


NEW QUESTION # 66
What is the maximum number of resources that can be displayed in flow charts created by SolarWinds' platform views?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B


NEW QUESTION # 67
Several resources are showing duplicate flow data. What is the most likely cause?

  • A. interfaces have duplicate entries in flow sources management
  • B. interfaces in flow sources management are set to drop
  • C. SolarWinds' NetFlow service needs to be restarted
  • D. source devices are configured to export flow data on ingress and egress

Answer: D


NEW QUESTION # 68
Which tool presents live flow traffic data sourced from/to a main polling engine server, providing basic insight into traffic on the main polling engine?

  • A. collector service
  • B. CBQoS/flow sources
  • C. flow navigator
  • D. local NetFlow source

Answer: D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
The local NetFlow source provides live (real-time) flow traffic data that is sourced to and from the main polling engine server. This feature is primarily for monitoring the main polling engine's traffic and quickly identifying top talkers and general flow activity on that server.
Reference:
"The Local NetFlow Source shows live NetFlow traffic sent to and from the main polling engine, giving insight into the traffic patterns for the main server."
- (Network Performance Monitor Administrator Guide, NetFlow Real-Time Tools section)


NEW QUESTION # 69
If an SNMP community string is changed on a device, which two of the following steps are required to re-establish successful polling on the node? (Choose two.)

  • A. Restart the SNMP service on the source device.
  • B. Update the community string in node properties.
  • C. Edit the node properties and save the changes.
  • D. Delete and add the node back into the platform.

Answer: B,C


NEW QUESTION # 70
......

Dumps of Hybrid-Cloud-Observability-Network-Monitoring Cover all the requirements of the Real Exam: https://pass4sure.examstorrent.com/Hybrid-Cloud-Observability-Network-Monitoring-exam-dumps-torrent.html